January 29, 2016, Washington, DC – Today the U.S. Chemical Safety Board (CSB) released a safety video into the fatal April 17, 2013, fire and explosion at the West Fertilizer Company in West, Texas, which resulted in 15 fatalities, 260 injuries, and widespread community damage. The deadly fire and explosion occurred when about thirty tons of fertilizer grade ammonium nitrate (FGAN) exploded after being heated by a fire at the storage and distribution facility.
The CSB’s newly released 12-minute safety video entitled, “Dangerously Close: Explosion in West, Texas,” includes a 3D animation of the fire and explosion as well as interviews with CSB investigators and Chairperson Vanessa Allen Sutherland. The video can be viewed on the CSB’s website and YouTube.
Chairperson Sutherland said, “This tragic accident should not have happened. We hope that this video, by sharing lessons learned from our West Fertilizer Company investigation, will help raise awareness of the hazards of fertilizer grade ammonium nitrate so that a similar accident can be avoided in the future.”
The CSB’s investigation found that several factors contributed to the severity of the explosion, including poor hazard awareness and fact that nearby homes and business were built in close proximity to the West Fertilizer Company over the years prior to the accident. The video explains that there was a stockpile of 40 to 60 tons of ammonium nitrate stored at the facility in plywood bins on the night of the explosion. And although FGAN is stable under normal conditions, it can violently detonate when exposed to contaminants in a fire.
In the video, Team Lead Johnnie Banks says, “We found that as the city of West crept closer and closer to the facility, the surrounding community was not made aware of the serious explosion hazard in their midst. And the West Fertilizer Company underestimated the danger of storing fertilizer grade ammonium nitrate in ordinary combustible structures.”
The CSB investigation concludes that this lack of awareness was due to several factors, including gaps in federal regulatory coverage of ammonium nitrate storage facilities. The video details safety recommendations made to OSHA and the EPA to strengthen their regulations to protect the public from hazards posed by FGAN.
Finally, the video explains how inadequate emergency planning contributed to the tragic accident. The CSB found that the West Volunteer Fire Department was not required to perform pre-incident planning for an ammonium nitrate-related emergency, nor were the volunteer firefighters required to attend training on responding to fires involving hazardous chemicals. As a result, the CSB made several safety recommendations to various stakeholders, including the EPA, to better inform and train emergency responders on the hazards of FGAN and other hazardous chemicals.
Chairperson Vanessa Allen Sutherland said, “The CSB’s goal is to ensure that no one else be killed or injured due to a lack of awareness of hazardous chemicals in their communities. If adopted, the Board’s recommendations can help prevent disasters like the one in West, Texas.”
The CSB is an independent federal agency charged with investigating serious chemical accidents. The agency's board members are appointed by the President and confirmed by the Senate. CSB investigations look into all aspects of chemical accidents, including physical causes such as equipment failure as well as inadequacies in regulations, industry standards, and safety management systems. The Board does not issue citations or fines but makes safety recommendations to companies, industry organizations, labor groups, and regulatory agencies such as OSHA and EPA. Please visit our website, www.csb.gov.
For more information, contact Communications Manager Hillary Cohen at [email protected] or by phone at 202.446.8095.