The CSB issues safety recommendations to prevent the recurrence or reduce the likelihood or consequences of similar incidents or hazards in the future. Recommendations are issued to a variety of parties, including government entities, safety organizations, trade unions, trade associations, corporations, emergency response organizations, educational institutions, and public interest groups. Recommendations are published in CSB reports and are closed only by vote of the Board. The CSB tracks all recommendations and communicates regularly with recommendations recipients to ensure that the recommended corrective actions are implemented. For more information, see Frequently Asked Questions about CSB recommendations.
2007-6-I-KS-4
Recommend to your membership companies that prepare MSDSs to update the MSDSs to: -Identify and include a warning for materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks. -Include a statement that bonding and grounding may be insufficient to eliminate the hazard from static-accumulating flammable liquids, and provide examples of additional precautions and references to the relevant consensus guidance (e.g., NFPA 77, Recommended Practice on Static Electricity (2007), and API Recommended Practice 2003, Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents (2008)). -Include conductivity testing data for the materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks. Status: Closed - Acceptable Action
Recommend to your membership companies that prepare MSDSs to update the MSDSs to: -Identify and include a warning for materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks. -Include a statement that bonding and grounding may be insufficient to eliminate the hazard from static-accumulating flammable liquids, and provide examples of additional precautions and references to the relevant consensus guidance (e.g., NFPA 77, Recommended Practice on Static Electricity (2007), and API Recommended Practice 2003, Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents (2008)). -Include conductivity testing data for the materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks.
2007-6-I-KS-3
Revise ANSI Z400.1 to advise chemical manufacturers and importers that prepare MSDSs to: -Identify and include a warning for materials that are static-accumulators and that may form ignitable vapor-air mixtures in storage tanks; -Advise users that bonding and grounding may be insufficient to eliminate the hazard from static-accumulating flammable liquids, and provide examples of additional precautions and references to the relevant consensus guidance (e.g., NFPA 77, Recommended Practice on Static Electricity (2007), and API Recommended Practice 2003, Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents (2008)); and -Provide conductivity testing data for materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks. Status: Closed - Acceptable Action
Revise ANSI Z400.1 to advise chemical manufacturers and importers that prepare MSDSs to: -Identify and include a warning for materials that are static-accumulators and that may form ignitable vapor-air mixtures in storage tanks; -Advise users that bonding and grounding may be insufficient to eliminate the hazard from static-accumulating flammable liquids, and provide examples of additional precautions and references to the relevant consensus guidance (e.g., NFPA 77, Recommended Practice on Static Electricity (2007), and API Recommended Practice 2003, Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents (2008)); and -Provide conductivity testing data for materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks.
2007-6-I-KS-5
2007-6-I-KS-6
2007-6-I-KS-7
2007-6-I-KS-8
2007-6-I-KS-1
Revise the "Guidance for Hazard Determination for compliance with the OSHA Hazard Communication Standard" to advise chemical manufacturers and importers that prepare MSDSs to: -Evaluate flammable liquids to determine their potential to accumulate static electricity and form ignitable vapor-air mixtures in storage tanks. -Test the conductivity of the flammable liquid and include the testing results in the MSDS. Status: Open - Acceptable Response or Alternate Response
Revise the "Guidance for Hazard Determination for compliance with the OSHA Hazard Communication Standard" to advise chemical manufacturers and importers that prepare MSDSs to: -Evaluate flammable liquids to determine their potential to accumulate static electricity and form ignitable vapor-air mixtures in storage tanks. -Test the conductivity of the flammable liquid and include the testing results in the MSDS.
2007-6-I-KS-2
Prior to the next revision, communicate to the Sub-Committee on the Globally Harmonized System of Classification and Labeling of Chemicals (SCEGHS) the need to amend the GHS to advise chemical manufacturers and importers that prepare MSDSs to: -Identify and include a warning for materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks. -Advise users that bonding and grounding may be insufficient to eliminate the hazard from static-accumulating flammable liquids, and provide examples of additional precautions and references to the relevant consensus guidance (e.g., NFPA 77, Recommended Practice on Static Electricity (2007), and API Recommended Practice 2003, Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents (2008)). -Provide conductivity testing data for materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks. Status: Closed - Acceptable Action
Prior to the next revision, communicate to the Sub-Committee on the Globally Harmonized System of Classification and Labeling of Chemicals (SCEGHS) the need to amend the GHS to advise chemical manufacturers and importers that prepare MSDSs to: -Identify and include a warning for materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks. -Advise users that bonding and grounding may be insufficient to eliminate the hazard from static-accumulating flammable liquids, and provide examples of additional precautions and references to the relevant consensus guidance (e.g., NFPA 77, Recommended Practice on Static Electricity (2007), and API Recommended Practice 2003, Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents (2008)). -Provide conductivity testing data for materials that are static accumulators and that may form ignitable vapor-air mixtures in storage tanks.
2007-6-I-KS-9